Answers are grounded in this paper and cite their sources.
PURPOSE: To investigate the shear bond strength (SBS) of various primer/resin cement systems to monolithic zirconia under different levels of storage. MATERIALS AND METHODS: ). The samples were divided into three groups (n = 24) according to primer/cement system: Z-PRIME Plus/DUO-LINK (Bisco); Clearfil Ceramic Primer Plus/PANAVIA SA (Kuraray); and Single Bond Universal Adhesive/RelyX Ultimate (3M ESPE). After bonding was completed, each group was divided into two subgroups (n = 12) under different levels of 24-hour storage and thermocycling. The specimens were embedded in acrylic molds, and SBS tests were conducted. Modes of failure were also evaluated. The data were analyzed using one- and two-way analysis of variance (ANOVA) and Tukey Honest Significant Difference test. Significance was set at P < .05. RESULTS: The highest and lowest SBS values were observed in the Kuraray (12.52 ± 1.34 MPa) and Bisco (5.32 ± 0.54 MPa) systems, respectively, in the thermocycled groups (P < .05). Similarly, in short-term storage groups, Kuraray had the highest (16.47 ± 1.5 MPa) and Bisco the lowest (7.43 ± 1.06 MPa) SBS values (P < .05). Regardless of adhesive system used, thermocycling significantly decreased the SBS of all cement groups (P < .05). Of the failures, 49% were adhesive, 45% were mixed, and 6% were cohesive. CONCLUSION: A methacryloyloxydecyl dihydrogen phosphate-containing resin cement is recommended to provide a durable bond for monolithic zirconia.