Key result
Flow-mediated dilatation of the brachial artery was negatively correlated with von Willebrand factor levels during cardiopulmonary bypass surgery.
Why the study?
Does flow-mediated dilatation of the brachial artery correlate with serum endothelial biomarkers in evaluating acute endothelial injury after cardiopulmonary bypass?
Observational (n=27)
Does flow-mediated dilatation of the brachial artery correlate with serum endothelial biomarkers in evaluating acute endothelial injury after cardiopulmonary bypass?
Sonographic assessment of flow-mediated dilatation correlates with von Willebrand factor levels, allowing early detection of acute endothelial injury during cardiopulmonary bypass.
Answers are grounded in this paper and cite their sources.
May support noninvasive FMD monitoring for endothelial injury in CPB; hypothesis-generating and requires prospective validation before clinical use.
OBJECTIVES: The purpose of this study was to investigate the correlation between flow-mediated dilatation of the brachial artery and serum endothelial biomarkers and to discuss the feasibility of sonographic evaluation of acute endothelial injury during cardiopulmonary bypass (CPB) surgery. METHODS: Sonography was applied to determine the percentage of change in the brachial artery size during flow-mediated dilatation. Meanwhile, the plasma concentrations of endothelial-derived biomarkers, such as endothelin 1, nitric oxide, and von Willebrand factor, were measured to monitor the changes in endothelial function. We analyzed the correlation between flow-mediated dilatation and biomarkers during the perioperative period of CPB in 27 patients. RESULTS: All of the biomarkers changed dramatically, especially during the CPB period. There was a negative correlation between flow-mediated dilatation and von Willebrand factor (P = .001; R = -0.31). CONCLUSIONS: A CPB event has a substantial impact on endothelial function, and sonographic assessment of the percentage of change in the brachial artery size during flow-mediated dilatation allows early detection of acute endothelial function injury in cardiac surgery.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2017) conducted an observational in Acute endothelial injury during cardiopulmonary bypass surgery (n=27). Cardiopulmonary bypass (CPB) surgery was evaluated on Correlation between flow-mediated dilatation and von Willebrand factor (R = -0.31, p=.001). Flow-mediated dilatation of the brachial artery was negatively correlated with von Willebrand factor levels during cardiopulmonary bypass surgery.
Synapse has enriched 10 related papers. Consider them for comparative context: