This is the authors' abstract. We don't add key points for this paper.
In this paper, we demonstrate that, by adding a small amount of CF4(2%) into a compressed-air planar dielectric barrier discharge (DBD), one can effectively inactivate a B. subtilis spore up to 50 mm in width in the postdischarge jet region after ten passes of exposure of plasma plume (equivalent plasma exposure time of 1 s) for treatment distance of up to 14 mm for the spore concentration in the range of 105-107CFU/mL. A possible mechanism is proposed, i.e., the chemically active F atoms and CF (n= 1 - 3) are generated through the help of abundant excited nitrogen molecules in the postdischarge region.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2012) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: