LC-MS/MS can enable analyses on a reference method level in a routine laboratory, if stable isotope dilution internal standardization is applicable for an analyte. For many analytes, however, stable isotope-labeled internal standards are not available, and homologous compounds with a similar molecular structure must be used as an internal standard. The use of such homologs introduces a source of inaccuracy, because ion suppression (1)(2) and ion enhancement effects can have different impacts on the target analyte and the internal standard compound, respectively. This important pitfall of non-isotope dilution LC-MS/MS methods is illustrated by an observation we made in the context of monitoring the drug tacrolimus. We have used 2 LC-MS/MS instruments for the quantification of tacrolimus, a Waters Quattro Ultima (instrument 1, installed 2003) and a Waters Micro (instrument 2, installed 2006). Similar methods were used on both systems, employing protein precipitation followed by on-line solid-phase extraction for sample preparation, as described previously (3). Ascomycin was used as the internal standard. For logistical reasons, we implemented the same method on a third LC-MS/MS instrument (Waters Quattro LC, instrument 3, installed 2000). However, using instrument 3, we found the QC results to be unacceptably low, despite the use of identical preparations of commercial calibration materials as used for instrument 1 and instrument 2 (source A; Recipe, Munich, Germany; Lot 439). The QC samples were procured from a different commercial source (source B; Chromsystems, Munich, Germany). Within distinct analytical series on the 3 instruments, the multiple-reaction–monitoring peak areas in the trace of ascomycin (internal calibrator) were similar in calibration samples, QC samples, and patient samples. All 3 instruments were tuned individually to obtain maximum ion yield for the ammonium adduct of tacrolimus, with single mass resolution. Identical mobile phases were used for all 3 systems. To further investigate this observation, we procured calibration materials from source B and prepared a series of samples to be analyzed with the 3 instruments. This series included 6 calibrator samples from the 2 sources (A and B), and surplus whole blood from 20 random clinical samples submitted for tacrolimus quantification. After acquiring the primary data from the identical series on the 3 instruments, we performed 2 separate quantification runs on all 3 data systems. In the first quantification runs only the calibration materials from source A and in the second quantification runs only the calibration materials from source B were defined as calibrators. In this way, 6 different sets of results were generated for the 20 patient samples. Use of the calibration materials from source A yielded mean tacrolimus concentration results from instrument 3 that were approximately 30% lower than the results from instrument 1 and instrument 2 (Table 1 ). In contrast, with the materials from source B excellent agreement was observed between all 3 instruments. Very close correlation between the 6 series was found for all comparisons, with no outliers (r > 0.99). Thus, the disagreement between the results from the 3 instruments that occurred with the use of materials from source A for calibration was a constant calibration inaccuracy. Data for the quantification of tacrolimus in samples from 20 patients by LC-MS/MS, employing different instruments and different commercial calibration materials. Data for the quantification of tacrolimus in samples from 20 patients by LC-MS/MS, employing different instruments and different commercial calibration materials. After switching to calibration materials from source B, we obtained consistently acceptable internal and external QC results for instrument 3, and this system was used for clinical analyses. Explanations remain speculative for this observed bias, dependent on instrument and calibration material, in the quantification of tacrolimus by LC-MS/MS. We suspect that the calibration material lot from source A contained compounds that interfered in an instrument-specific manner with the ionization of the target analyte tacrolimus as an ion enhancement, but not with the ionization of ascomycin (the internal standard). Our observations highlight differential modulation of ionization efficacy of a target analyte and a respective internal standard compound by matrix constituents as an important potential source of error in LC-MS/MS methods in which the internal standard is a homologous compound instead of a stable isotope-labeled compound. Consequently, the important role of calibration material matrices in the accuracy of LC-MS/MS results must be considered in such methods. However, differential ion suppression or enhancement may also affect single individual samples of a series and may remain unrecognized. Not only such ionization-related effects, but also different stability of compounds, can introduce inaccuracy in non-isotope dilution LC-MS/MS methods (4). The development of stable isotope-labeled internal standards is thus of utmost importance for the application of LC-MS/MS in clinical laboratories. Our data furthermore underscore that the performance and interference characteristics of similar LC-MS/MS instruments can differ substantially, requiring instrument-specific method validation. Grant/Funding Support: None declared. Financial Disclosures: None declared.
No takes yet. Share an insight, caveat, or question.
Michael Vogeser (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: