Key result
Rhythmic lower-leg cuff inflation at 80 and 120 mmHg increased mean R-R interval and high-frequency power of RRI fluctuation during quiet standing compared to sham.
Why the study?
Does rhythmic lower-leg cuff inflation alter cardiovascular autonomic responses during quiet standing in healthy subjects?
Does rhythmic lower-leg cuff inflation alter cardiovascular autonomic responses during quiet standing in healthy subjects?
Rhythmic lower-leg cuff inflation at pressures of 80 mmHg or higher increases cardiac vagal outflow and opposes hydrostatic-induced venous pressure during standing in healthy subjects.
Answers are grounded in this paper and cite their sources.
May augment vagal activity during standing in healthy subjects; hypothesis-generating and should not yet change practice.
To determine the effects of muscle pump function on cardiac autonomic activity in response to quiet standing, we simulated the muscle pump effect by rhythmic lower-leg cuff inflation (RCI) with four cuff pressures of 0 (sham), 40, 80, and 120 mmHg at 5 cycles/min. The R-R interval (RRI) and beat-to-beat blood pressure (BP) were acquired in healthy subjects (6 males and 5 females, aged 21-24 yr). From the continuous BP measurement, stroke volume (SV) was calculated by a pulse-contour method. Using spectral and cross-spectral analysis, RRI and systolic BP variability as well as the gain of spontaneous cardiac baroreflex sensitivity (sBRS) were estimated for the low- and high-frequency (HF) bands. Compared with the sham condition, RCI with cuff pressures of 80 and 120 mmHg led to increases in the mean RRI (P < 0.01) and HF power of RRI fluctuation (P < 0.05 for 80 mmHg and P < 0.01 for 120 mmHg) during quiet standing. Reduction in SV during standing was suppressed, and the sBRS of the HF band for standing were increased by RCI for either cuff pressure (P < 0.05 for 80 mmHg and P < 0.01 for 120 mmHg). However, at 40 mmHg RCI, these remained unchanged. These results suggest that, during standing, RCI of the lower leg increases cardiac vagal outflow when the cuff pressure is raised enough to oppose the hydrostatic-induced venous pressure in the calf.
No takes yet. Share an insight, caveat, or question.
Niizeki et al. (2011) studied Healthy (n=11). Rhythmic lower-leg cuff inflation (RCI) vs. Sham (0 mmHg) was evaluated on Mean R-R interval (RRI) and high-frequency (HF) power of RRI fluctuation (p=<0.01). Rhythmic lower-leg cuff inflation at 80 and 120 mmHg increased mean R-R interval and high-frequency power of RRI fluctuation during quiet standing compared to sham.
Synapse has enriched 10 related papers. Consider them for comparative context: