Key result
An apical technique for catheterization of the left side of the heart is proposed for infants and children when standard venous or retrograde aortic routes are not feasible.
Answers are grounded in this paper and cite their sources.
Describes an apical technique for left heart catheterization in infants and children when standard approaches fail.
DIRECT hemodynamic study of the left ventricle has been accomplished in recent years by many approaches. In infancy and childhood it is often possible to pass a catheter into this ventricle via the venous route through the foramen ovale and mitral valve. When this is not possible, retrograde aortic catheterization usually permits entry into the left ventricle. In a limited number of situations catheterization of this ventricle or its outflow artery or both is not feasible by these relatively simple methods. To be useful in such situations a method must satisfy certain requirements: it must be applicable on infrequent occasions, . . .
No takes yet. Share an insight, caveat, or question.
Lurie et al. (1961) studied Need for left heart catheterization. Apical technique for catheterization of the left side of the heart was evaluated. An apical technique for catheterization of the left side of the heart is proposed for infants and children when standard venous or retrograde aortic routes are not feasible.
Synapse has enriched 10 related papers. Consider them for comparative context: