Key result
The redefined Acromion Index, calculated using a novel radiographic measurement technique, did not differ between patients with complete, partial, or no rotator cuff tears.
Why the study?
Although many radiographic parameters associated with rotator cuff tears have been described, the study aimed to measure the capacity to predict rotator cuff tears by reinterpreting the acromion index with a new radiographic measurement technique.
Does a redefined Acromion Index measurement on shoulder radiography predict rotator cuff tears in patients with shoulder pain?
Cross-Sectional (n=62)
No
Does a redefined Acromion Index measurement on shoulder radiography predict rotator cuff tears in patients with shoulder pain?
A redefined measurement technique for the Acromion Index on shoulder radiography does not predict the presence or severity of rotator cuff tears.
This is the authors' abstract. We don't add key points for this paper.
Background: Many radiographic parameters associated with rotator cuff tears (RCT) have been described. Our aim is to measure the capacity to predict RCT by reinterpreting the Acromion index (AI) with a new radiographic measurement technique. Methods: The shoulder magnetic resonance imaging (MRI) report of a total of 62 patients and AI measured with the new technique in shoulder radiographs were evaluated. On shoulder radiographs, the glenohumeral length was identified as the length between the lateral humerus tuberculum majus and the anterior midpoint of the glenoid joint. The glenoacromial length was also defined from a different perspective as the length between the lateral tip of the acromion and the anterior midpoint of the glenoid joint. Results: There was no significant difference in glenohumeral length between patients with complete and partial RCT and those without RCT (p value=0.163). There was no significant difference in glenoacromial length between these three groups of patients (Pvalue=0.110). It was concluded that there was no significant difference between the three groups of patients in terms of AI that we redefined (Pvalue=0.095). Conclusion: AI of the glenohumeral and glenoacromial lengths, which were redefined with a different measurement technique on the shoulder radiography, did not yield statistically significant results in the diagnosis of shoulder RCT.
Answers are grounded in this paper and cite their sources.
New AI measurement fails to predict rotator cuff tears on radiographs; leaves open the diagnostic value of redefined acromion index and requires larger validation studies.
No takes yet. Share an insight, caveat, or question.
Aydın et al. (2023) conducted a cross-sectional in Rotator Cuff Tears (n=62). Redefined Acromion Index vs. Patients without rotator cuff tears was evaluated on Difference in redefined Acromion Index among patients with complete, partial, and no rotator cuff tears (p=0.095). The redefined Acromion Index, calculated using a novel radiographic measurement technique, did not differ between patients with complete, partial, or no rotator cuff tears.
Synapse has enriched 10 related papers. Consider them for comparative context: