Key result
Noninvasive quantification of central venous pressure by ultrasound showed significant correlation with invasive measurements.
Why the study?
Does noninvasive quantification of central venous pressure by ultrasound accurately correlate with invasive measurement in patients requiring intraoperative or postoperative management?
Observational (n=76)
Does noninvasive quantification of central venous pressure by ultrasound accurately correlate with invasive measurement in patients requiring intraoperative or postoperative management?
A novel ultrasound-based method for noninvasive central venous pressure measurement demonstrates strong correlation and agreement with invasive catheter measurements.
Answers are grounded in this paper and cite their sources.
Ultrasound CVP estimation appears feasible; hypothesis-generating and requires prospective validation before any clinical use.
BACKGROUND: The central venous pressure (CVP) is essential for assessing the cardiac preload and circulating blood volume in clinic. The invasive CVP measurement by central venous catheter has been reported with various complications. The aim of this study was to develop a new noninvasive method for quantification of CVP by ultrasound. METHODS AND RESULTS: Seventy-six patients who had their CVP monitored for intraoperative or postoperative management were recruited. By accurate location of the collapse point of the internal jugular vein and the center of the right atrium using ultrasound imaging, the height of the fluid column between those 2 points was measured as the noninvasive CVP (CVPn). A total of 118 measurements were performed and compared with the invasive CVP (CVPi). Linear correlation analysis revealed a significant correlation between CVPi and CVPn (preoperative measurements, r=0.90; P<0.01 and postoperative measurements, r=0.93; P<0.01). Bland-Altman plots showed a good agreement between CVPi and CVPn with the mean difference of 0.22 mm Hg (preoperative measurements) and -0.09 mm Hg (postoperative measurements), respectively. CONCLUSIONS: The new noninvasive CVP quantification method based on the location of both the collapse point of internal jugular vein and the center of right atrium by ultrasound could be used as a reliable approach for monitoring the hemodynamic status in clinic.
No takes yet. Share an insight, caveat, or question.
Xing et al. (2015) conducted an observational in Patients requiring central venous pressure monitoring (n=76). Noninvasive quantification of central venous pressure by ultrasound vs. Invasive central venous pressure measurement was evaluated on Correlation and agreement between noninvasive and invasive CVP measurements (r=0.90 (preoperative) and r=0.93 (postoperative), p=<0.01). Noninvasive quantification of central venous pressure by ultrasound showed significant correlation with invasive measurements.
Synapse has enriched 10 related papers. Consider them for comparative context: