Answers are grounded in this paper and cite their sources.
Pentachlorophenol (PCP) was measured in wood following extraction with methanol:0.1% acetic acid. The extract was derivatized with acetic anhydride in a biphasic solvent containing toluene and 0.1 M Na 2 CO 3 (pH 11.4), and pentachlorophenyl acetate was quantitated by gas chromatography−mass spectrometry (GC−MS) using [ 13 C 6 ]PCP as an internal standard. A second detection method employed thin layer chromatography (TLC) after nitric acid-mediated oxidation of PCP to tetrachloro-1,4-benzoquinone. The third method was by colorimetry and required a liquid−liquid partitioning of PCP under acidic and alkaline pH against toluene. Then, PCP was coupled to 4-aminoantipyrine in the presence of sodium persulfate to form a dye which was measured at 580 nm. The limit of detection approached 50 ppb by GC−MS and 1 ppm by TLC when 100 mg of wood was used for analysis and 1 ppm for the colorimetric method when 1 g of wood was used for detection. The estimates of PCP were comparable for all three methods.
No takes yet. Share an insight, caveat, or question.
Gremaud et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: