Key result
Modified TEG assays using Ecarin and human factor Xa showed strong correlation between reaction time R and concentrations of dabigatran, rivaroxaban, and apixaban (r=0.96, 0.84, 0.86; p<0.0001).
Why the study?
Monitoring direct oral anticoagulants (DOACs) would be useful in situations like bleedings and trauma, prompting evaluation of thromboelastography assays for this purpose.
Can modified TEG 5000 assays using Ecarin and human factor Xa accurately measure the anticoagulant effect of DOACs in healthy volunteers?
Can modified TEG 5000 assays using Ecarin and human factor Xa accurately measure the anticoagulant effect of DOACs in healthy volunteers?
Modified TEG 5000 assays using Ecarin and human factor Xa can accurately monitor the anticoagulant effect of DOACs, showing strong correlation with drug concentrations.
Answers are grounded in this paper and cite their sources.
Modified TEG assays may detect dabigatran effects; leaves open clinical monitoring utility pending validation in patients.
There are situations where monitoring direct oral anticoagulants (DOACs) would be useful, including bleedings and trauma. The thromboelastographic technique has proven useful in bleeding situations in trauma and heart surgery. The aim of this study was to examine the effect of DOACs on all currently commercially available conventional TEG®5000 assays as well as novel modified assay using Ecarin and human factor Xa (HFXa). Healthy male volunteers were given single dose of oral dabigatran 150 mg, rivaroxaban 20 mg, or apixaban 5 mg. Kaolin, RapidTEG, functional fibrinogen, PlateletMapping assay, and novel modified assays using Ecarin and HFXa were prepared. All TEG parameters were recorded. DOAC concentrations were correlated to the parameters with highest response to the DOAC effect. Sensitivity and negative predictive value of the parameter with highest response to DOAC concentration of 50 ng/mL was calculated. None of the conventional TEG assays demonstrated significant response to the effect on apixaban. Using Ecarin, reaction time R was strongly correlated with dabigatran concentrations. Using HFXa assay, R was strongly correlated with rivaroxaban and apixaban concentrations: r = 0.96, 0.84, and 0.86, respectively; p < 0.0001 for all. The R times obtained with the modified assays demonstrated strong sensitivity and negative predictive values for DOAC levels of ≥50 ng/mL. We have demonstrated that TEG®5000 can monitor the DOAC effect on hemostasis when the appropriate activator is used with significant correlation with DOAC concentrations. Larger clinical studies are warranted for correlation of TEG profile and clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Artang et al. (2022) studied Healthy volunteers. Modified TEG assays using Ecarin and human factor Xa vs. Conventional TEG assays was evaluated on Correlation of reaction time R with DOAC concentrations (r = 0.96, 0.84, and 0.86, p=<0.0001). Modified TEG assays using Ecarin and human factor Xa showed strong correlation between reaction time R and concentrations of dabigatran, rivaroxaban, and apixaban (r=0.96, 0.84, 0.86; p<0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: