Answers are grounded in this paper and cite their sources.
(1) Although the accuracy of static computer-aided implant surgery (sCAIP) is well reported, information on its long-term effect on peri-implant health and complications is scarce. (2) Twenty-six patients initially treated were recalled. Implant survival, radiographic bone level, peri-implant health, and complications were registered. A multilevel regression model was applied to study the relationship between the research variables. (3) Sixteen patients participated in this study (average age 58.5 years; range 27.8-73.8). The mean follow-up time was 9.1 years (range 7.3-11.3). Two implants failed, resulting in a survival rate of 97.1%. The mean bone level change corresponded to a loss of 0.63 mm (SD 1.90) for the whole group, 0.17 mm (SD 1.46), and 0.91 mm (SD 2.09) for tooth- and mucosa-supported guides, respectively. The mean PPD for the total group was 4.24 mm (SD 1.25), and 3.79 mm (SD 0.97) and 4.51 mm (SD 1.33) for the tooth- and mucosa-supported guides, respectively. Four implants (6.3%) were diagnosed with peri-implantitis. Coronal deviation was slightly associated with having a negative impact on bone level at follow-up, but this was not statistically significant. Seven patients (43.8%) experienced technical complications. Biological complications were seen in 3/16 patients (18.75%). (4) SCAIP may contribute to more predictable implant placement; the long-term clinical outcome is similar to conventional nonguided surgery.
No takes yet. Share an insight, caveat, or question.
Naeini et al. (2023) studied this question.