Key result
Transcatheter aortic valve-in-valve implantation without contrast or echo guidance reduced mean transaortic gradient from 39.4 to 20 mmHg at 30 days (p<0.001) with no deaths or strokes.
Why the study?
Transcatheter ViV implantation is an emerging treatment for degenerative surgical bioprostheses, and radiopaque SAV frames may enable procedures under local anesthesia without contrast aortography or echocardiographic guidance.
Does transcatheter aortic valve-in-valve implantation without contrast aortography or echocardiographic guidance improve hemodynamics and clinical outcomes safely in patients with failed surgical bioprosthetic valves?
Observational (n=37)
Does transcatheter aortic valve-in-valve implantation without contrast aortography or echocardiographic guidance improve hemodynamics and clinical outcomes safely in patients with failed surgical bioprosthetic valves?
p-value: p=<0.001
A minimalist approach to transcatheter aortic valve-in-valve implantation using only fluoroscopic guidance and local anesthesia is feasible, safe, and yields significant hemodynamic improvements at 30 days.
Objectives To demonstrate safety, feasibility and short‐term clinical outcomes after transcatheter aortic valve‐in‐valve (ViV) implantation under local anesthesia without contrast aortography or echocardiographic guidance. Background Transcatheter ViV implantation is an emerging treatment modality for patients with degenerative surgical bioprostheses. Given the radiopaque properties of the surgical aortic valve (SAV) frame, ViV procedures can often be performed with fluoroscopic guidance alone. Methods ViV implantation was performed in 37 patients with SAV failure under local anesthesia without contrast aortography. Clinical and echocardiographic data were obtained at baseline, discharge, and 30 days. Results Mean age was 74 ± 10 years and STS predicted risk of mortality was 5.6 ± 2.4%. Mean transaortic gradient decreased from 39.4 ± 15.5 mmHg to 13 ± 6.3 mmHg at discharge (p < .001), and 20 ± 7.5 mmHg at 30 days (p < .001 compared to baseline), aortic valve area increased from 0.9 ± 0.3 cm2 to 1.2 ± 0.4 cm2 at 30 days (p = .007). No patient had more than mild aortic regurgitation. Hospital discharge occurred at a median of 2.6 ± 4.4 days. At 30‐day follow‐up there were no deaths, myocardial infarctions, strokes, repeat hospital admissions for heart failure, or renal failure. One patient (2.7%) required a new pacemaker. 93% of the patients were in New York Heart Association functional class I or II. Conclusions Transcatheter aortic ViV implantation for selected patients with degenerative surgical bioprostheses under local anesthesia without aortography or echocardiographic guidance is feasible and safe.
No takes yet. Share an insight, caveat, or question.
Attinger‐Toller et al. (2019) conducted an observational in Surgical aortic valve failure (n=37). Transcatheter aortic valve-in-valve implantation without contrast aortography or echocardiographic guidance was evaluated on Mean transaortic gradient at 30 days (p=<0.001). Transcatheter aortic valve-in-valve implantation without contrast or echo guidance reduced mean transaortic gradient from 39.4 to 20 mmHg at 30 days (p<0.001) with no deaths or strokes.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: