Answers are grounded in this paper and cite their sources.
Accelerating rate calorimetry (ARC) is used to compare the reactions between Li x CoO 2 (4.2 V) or Li x Mn 2 O 4 (4.2 V) and an equal mass of 1 M LiPF 6 (ethylene carbonate/diethyl carbonate) electrolyte. The ARC results show that under these conditions, the self-heating rates and hence thermal power are significantly larger for Li x Mn 2 O 4 than for Li x CoO 2 . This result is not consistent with the results of oven exposure tests on 18650 size cells using the same materials, where higher temperatures are needed to initiate thermal runaway for cells with Li x Mn 2 O 4 cathodes. The amount of reaction heat generated by the reaction of Li x CoO 2 with 1 M electrolyte is independent of the electrode/electrolyte mass ratio (at least for the first reaction process), while that generated by the reaction of Li x Mn 2 O 4 with electrolyte increases with electrolyte amount. ARC experiments using an approximate 1:6 electrolyte to electrode mass ratio, which mirrors the conditions found in 18650 cells, demonstrate that Li x CoO 2 is much more reactive than Li x Mn 2 O 4 , as is observed in commercial cells. The work presented here suggests that the safety of Li-ion cells using LiMn 2 O 4 cathodes can be improved by decreasing the positive electrode porosity.
No takes yet. Share an insight, caveat, or question.
MacNeil et al. (2001) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: