Computer calculations were used to simulate the effects of thermal shock on the stresses developed in porcelain-fused-to-metal (PFM) systems. A three-dimensional-finite-element model was employed to first calculate time-dependent temperature distribution in a beam shaped specimen 1.25-2.5×8×20mm. These were then used in a two-dimensional analysis of stresses in a beam consisting of 50 elements. Transient stresses in a beam consisting of 50 elements were calculated for porcelain, porcelain with an opaque layer, and porcelain-opaque-alloy system; the effects of porcelain thickness, thermal expansion coefficients, and quenching temperatures were evaluated. Experimental tests were also conducted for correlation with the theoretical calculations.Results show that for αm(metal)<αp(porcelain), the highest stresses occur on the surface, and the interface stress is lower than αm=αp. When αm>αp, the surface stress is lower, and the interface stress is higher than αm=αp. When αp-αm>2×10-6°C-1, cracks are more easily initiated in the porcelain surface rather than the interface. Theory and experiment are in general agreement.
No takes yet. Share an insight, caveat, or question.
Asaoka et al. (1986) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: