Key result
Meal challenge significantly increased temporally averaged flow velocity in the distal straight section of the superior mesenteric artery (166.9 vs. 96.2 mm/s, P=0.0313), making it the optimal plane.
Why the study?
Although 2D cine phase contrast MRI is standard velocimetry for the superior mesenteric artery, the optimal localization of the measurement plane had never been fully discussed.
Does the localization of the measurement plane affect flow velocimetry of the superior mesenteric artery using 2D cine PC-MRI?
Observational (n=7)
No
Does the localization of the measurement plane affect flow velocimetry of the superior mesenteric artery using 2D cine PC-MRI?
Absolute Event Rate: 166.9% vs 96.2%
p-value: p=0.0313
For superior mesenteric artery velocimetry using 2D cine PC-MRI, the distal straight section is recommended over the curved mid section to accurately detect post-prandial blood flow increases.
Plane selection affects postprandial SMA velocity by 2D cine PC-MRI; distal straight section may optimize measurements but requires validation in patients.
PURPOSE: 2D cine phase contrast (PC)-MRI is a standard velocimetry for the superior mesenteric artery (SMA); however, the optimal localization of the measurement plane has never been fully discussed previously. The purpose of this Institutional Review Board approved prospective and single arm study is to test whether flow velocimetry of the SMA with combined use of 2D cine PC-MRI and meal challenge is dependent on the localizations of the measurement planes and to seek optimal section for velocimetry. METHODS: Seven healthy volunteers underwent cardiac phase resolved ECG gated 2D cine PC-MRI pre- and 30 min post-meal challenge at three measurement planes: proximal, curved mid section and distal straight section of the SMA at 3T. 4D Flow using 3D cine PC-MRI with vastly undersampled isotropic projection imaging (PC VIPR) was also performed right after 2D cine PC-MRI to delineate the flow dynamics within the SMA using streamline analysis. Two radiologists measured flow velocities, and rated the appearances of the abnormal flow in the SMA on streamlines derived from the 4D Flow and the computational fluid dynamics (CFD). RESULTS: 2D cine PC-MRI measured increased temporally averaged flow velocity (mm/s) after the meal challenge only in the proximal (129.3 vs. 97.8, P = 0.0313) and distal section (166.9 vs. 96.2, P = 0.0313), not in the curved mid section (113.1 vs. 85.5, P = 0.0625). The average velocities were highest and their standard errors (8.5-26.5) were smallest at the distal straight section both before and after the meal challenge as compared with other sections. The streamline analysis depicted more frequent appearances of vertical or helical flow in the curved mid section both on 4D Flow and CFD (κ: 0.27-0.68). CONCLUSION: SMA velocimetry with 2D cine PC-MRI was dependent on the localization of the measurement planes. Distal straight section, not in the curved mid section is recommended for MR velocimetry.
No takes yet. Share an insight, caveat, or question.
Sugiyama et al. (2020) conducted an observational in Healthy volunteers (n=7). Meal challenge vs. Pre-meal baseline was evaluated on Temporally averaged flow velocity at the distal straight section of the SMA (mm/s) (p=0.0313). Meal challenge significantly increased temporally averaged flow velocity in the distal straight section of the superior mesenteric artery (166.9 vs. 96.2 mm/s, P=0.0313), making it the optimal plane.