Answers are grounded in this paper and cite their sources.
The work addresses a particular case of interaction between adhesive and abrasive wear in the electrical contact field, characterized by a selective adhesive transfer layer. The system studied is composed of a resistive element (NiCr thin layer) and a contactor (AgPd), forming an angular position sensor lubricated with a standard silicone oil/PTFE grease. The angular position/electrical resistance relationship is disturbed by wear of the NiCr surfaces, enhanced by the formation on the AgPd contactor of a third body enriched in Ni. From a practical point of view, it has been found that this detrimental Ni-selective transfer formation can be controlled by inserting tumble finishing with lamellar alumina powder as the last step of NiCr track manufacturing. Acting like a solid lubricant, alumina clusters of 1–5 µm in size adhere to NiCr surface giving rise to a delay or cancel of Ni adhesion on the contactor which lead to a significant improvement of electrical behavior of the position sensor.
No takes yet. Share an insight, caveat, or question.
Isard et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: