An experiment on electron beam energy recovery systems has been performed using a laser-heated electron gun and a multistage electron collector. Modeling of the laser heating indicates that the cathode temperature is proportional to the one-fourth power of laser power. The energy recovery efficiency of 99.8% of the designed collector is calculated using a computer code with a beam current of about 10 mA and -75 keV. In the first phase of the recovery experiment, potentials of the collector electrodes are provided through a voltage divider of several hundred megaohms. In order to overcome the drawback of voltage-divider resistance, two high-voltage power supplies are provided in the second phase of the experiment, and charge and energy recovery efficiencies are measured.
No takes yet. Share an insight, caveat, or question.
Roy et al. (1999) studied this question.