Key result
Amniotic fluid nt-proBNP to total protein ratio demonstrated high specificity (0.97) and a positive likelihood ratio of 4.3 for confirming fetal myocardial dysfunction.
Why the study?
Does amniotic fluid nt-proBNP measurement accurately diagnose fetal myocardial dysfunction in fetuses with known or suspected cardiac load?
Case-Control (n=391)
No
Does amniotic fluid nt-proBNP measurement accurately diagnose fetal myocardial dysfunction in fetuses with known or suspected cardiac load?
Answers are grounded in this paper and cite their sources.
Amniotic fluid nt-proBNP measurement is highly specific for confirming fetal myocardial dysfunction and correlates well with fetal blood levels, offering a less invasive adjunct to fetal blood sampling.
BACKGROUND: Myocardial dysfunction occurs in a variety of fetal disorders. Findings from adult cardiology, where n-terminal pro-B-type natriuretic peptide (nt-proBNP) is an established biomarker of left ventricular dysfunction have been extended to fetal life. Since fetal blood sampling is technically challenging we investigated amniotic fluid nt-proBNP for its suitability to diagnose fetal myocardial dysfunction. METHODS: Ultrasound, Doppler examination and echocardiography was applied to classify cases and controls. Amniotic fluid nt-proBNP to amniotic fluid total protein ratio was calculated and compared to the gestational age-dependent reference intervals. In a subset of cases, fetal and maternal plasma nt-proBNP levels were determined. RESULTS: Specimen from 391 fetuses could be analyzed (171 cases, 220 controls). There was a high correlation between amniotic fluid and fetal blood nt-proBNP levels (r = 0.441 for cases; r = 0.515 for controls), whereas no correlation could be detected between maternal and fetal (blood and amniotic fluid) nt-proBNP concentrations. Specificity and positive likelihood ratio of amniotic fluid nt-proBNP to amniotic fluid total protein ratio were high (0.97 and 4.3, respectively). CONCLUSION: Amniotic fluid nt-proBNP measurement allows diagnostic confirmation of fetal myocardial dysfunction. It may serve as a useful adjunct in addition and correlation to existing tests of myocardial function, particularly in the context of invasive fetal therapy, where access to the amniotic cavity is part of the procedure.
No takes yet. Share an insight, caveat, or question.
Leufgen et al. (2017) conducted a case-control in Fetal myocardial dysfunction (n=391). Amniotic fluid nt-proBNP to total protein ratio vs. Fetuses without cardiac load (controls) was evaluated on Diagnostic accuracy for fetal myocardial dysfunction (Specificity 0.97, positive likelihood ratio 4.3). Amniotic fluid nt-proBNP to total protein ratio demonstrated high specificity (0.97) and a positive likelihood ratio of 4.3 for confirming fetal myocardial dysfunction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: