Key result
A novel non-invasive method using pulse oximetry to estimate optimal AV delay in dual-chamber paced patients demonstrated a strong positive correlation with standard invasive aortic blood pressure measurements.
Why the study?
Does pulse oximetry accurately estimate the optimal AV delay compared to invasive aortic blood pressure measurement in dual-chamber paced patients?
Observational (n=24)
No
Does pulse oximetry accurately estimate the optimal AV delay compared to invasive aortic blood pressure measurement in dual-chamber paced patients?
Pulse oximetry provides a highly correlated, non-invasive alternative to invasive aortic blood pressure measurement for optimizing AV delay in patients with dual-chamber pacemakers.
Answers are grounded in this paper and cite their sources.
Supports further evaluation of pulse oximetry for AV delay optimization; hypothesis-generating and should not yet change practice.
The paper gives a detailed description of a new method for estimating the optimal AV delay in dual chamber paced patients, which is non-invasive, not dependent on the examinator, not time consuming and inexpensive. In principle, the pulse oximetry signal obtained by common finger probe was used to measure the change in its time course after changes in pacemaker stimulation. The Eagle 4000 monitor, manufactured by Marquette USA, was used for measurements and digitizing the data and then this data was analyzed using a portable personal computer with original programs developed in Famulus v. 3.5. Our results were compared to the standard method for optimizing AV delay which uses the direct measurement of blood pressure in the ascending aorta. Twenty-four patients with Physios pacemakers were enrolled in the pilot study. Measurements showed a positive correlation (r = 0.982, N = 432) between the changes in the pulse oximetry amplitude and changes in the pressure pulse amplitude measured in the ascending aorta by a catheter-tip manometer. These results indicated that this new method could be a possible alternative to the currently used techniques for AV interval optimization.
No takes yet. Share an insight, caveat, or question.
Měšťan et al. (1998) conducted an observational in Patients with dual chamber pacemakers (sick sinus syndrome or complete AV block) (n=24). Pulse oximetry method for estimating optimal AV delay vs. Direct measurement of blood pressure in the ascending aorta was evaluated on Correlation between changes in pulse oximetry amplitude and changes in pressure pulse amplitude (r = 0.982). A novel non-invasive method using pulse oximetry to estimate optimal AV delay in dual-chamber paced patients demonstrated a strong positive correlation with standard invasive aortic blood pressure measurements.
Synapse has enriched 10 related papers. Consider them for comparative context: