Key result
Implementation of a hub-and-spoke system-of-care improved IRA patency rates and reduced lysis-to-angiogram times.
Why the study?
Does the implementation of a hub-and-spoke system-of-care model improve angiographic outcomes and reduce time delays in patients undergoing pharmacoinvasive management for STEMI?
Observational (n=407)
Single-blind
Yes
Does the implementation of a hub-and-spoke system-of-care model improve angiographic outcomes and reduce time delays in patients undergoing pharmacoinvasive management for STEMI?
Answers are grounded in this paper and cite their sources.
Implementation of a hub-and-spoke system-of-care for STEMI significantly reduces lysis-to-angiogram times and improves infarct-related artery patency in patients undergoing a pharmacoinvasive strategy.
OBJECTIVES: We evaluated the impact of implementation of the TN-STEMI programme on various characteristics of the pharmacoinvasive group by comparing clinical as well as angiographic outcomes between the pre- and post-implementation groups. METHODS: The TN-STEMI programme involved 2420 patients of which 423 patients had undergone a pharmacoinvasive strategy of reperfusion. Of these, 407 patients had a comprehensive blinded core-lab evaluation of their angiograms post-lysis and clinical evaluation of various parameters including time-delays and adverse cardio- and cerebro-vascular events at 1year. Streptokinase was used as the thrombolytic agent in 94.6% of the patients. RESULTS: In the post-implementation phase, there was a significant improvement in 'First medical contact (FMC)-to-ECG' (11 vs. 5min, p<0.001) and 'Lysis-to-angiogram' (98.3 vs. 18.2h, p<0.001) times. There was also a significant improvement in the number of coronary angiograms performed within 24h (20.7% vs. 69.3%, p<0.001). The 'Time-to-FMC' (160 vs. 135min, p=0.07) and 'Total ischemic time' (210 vs. 176min, p=0.22) also showed a decreasing trend. IRA patency rate (70.2% vs. 86%, p<0.001) and thrombus burden (TIMI grade 0: 49.1% vs. 73.4%, p<0.001) were superior in this group. The MACCE rates were similar except for fewer readmissions (29.8% vs. 12.6%, p=0.0002) and target revascularizations at 1year (4.8% vs. none, p=0.002) in the post-implementation group. CONCLUSION: The implementation of a system-of-care (hub-and-spoke model) in the pharmacoinvasive group of the TN-STEMI programme demonstrated shorter lysis-to-angiogram times, better TIMI flow patterns and lower thrombus burden in the post-implementation phase.
No takes yet. Share an insight, caveat, or question.
Raja et al. (2017) conducted an observational in ST-elevation myocardial infarction (STEMI) (n=407). Implementation of the TN-STEMI programme (hub-and-spoke model) vs. Pre-implementation phase was evaluated on IRA patency rate (p=<0.001). Implementation of a hub-and-spoke system-of-care improved IRA patency rates and reduced lysis-to-angiogram times.
Synapse has enriched 10 related papers. Consider them for comparative context: