Key result
The Intramedullary Hip Screw for reverse oblique intertrochanteric femoral fractures achieved satisfactory fracture reduction in 88% of patients, with a 30-day mortality of 6.5%.
Why the study?
Does the Intramedullary Hip Screw (IMHS) provide satisfactory clinical and radiological outcomes in patients with reverse oblique intertrochanteric femoral fractures?
Cohort (n=63)
No
Does the Intramedullary Hip Screw (IMHS) provide satisfactory clinical and radiological outcomes in patients with reverse oblique intertrochanteric femoral fractures?
The Intramedullary Hip Screw provides satisfactory clinical and radiological outcomes for unstable reverse oblique intertrochanteric femoral fractures, comparable to other cephalo-medullary devices.
May support IMHS for reverse oblique fractures; leaves open need for RCTs versus other cephalo-medullary devices.
Aims: Reverse oblique intertrochanteric fractures (OTA/ AO 31-A3) have unique biomechanical properties that confer difficulties in obtaining stable fixation with the conventional sliding dynamic condylar screw. Recent studies have recommended the use of cephalocondylic intramedullary devices for these unstable fractures. Both the Proximal Femoral Nail (PFN) and the Gamma Nail (GN) have shown good outcome results but the results of treatment with the IMHS have not been reported in the literature. Methods: Between 1999–2008 6724 consecutive hip fractures were treated at our institute. There were 2586 extracapsular fractures and 307 subtrochanteric fractures. 115 of the extracapsular fractures had a reverse oblique pattern and 63 of these were treated with the IMHS. We retrospectively reviewed clinical and radiological records for the reverse oblique intertrochanteric fractures treated with the IMHS. Follow-up duration ranged from 8 months to 6 years. Results: Among the 63 patients treated with the IMHS, 56 (88%) fractures were reduced satisfactorily with only one poorly positioned hip screw in the femoral head. There were no cases of femoral shaft fracture, screw cut-out or collapse at the fracture site. The orthopaedic complications were two cases of mal-rotation, two cases of non-union, two cases of distal locking bolts backing out, and one cracked nail. 30 day mortality was 6.5%. Conclusion: Cephalo-medullary nailing devices have been recommended for the treatment of reverse oblique intertrochanteric femoral fractures. Our clinical and radiological outcomes with the IMHS compare favourably to the results in reports where other cephalo-medullary devices have been used. Therefore we consider the IMHS a good option for the treatment of these unstable fractures.
No takes yet. Share an insight, caveat, or question.
Chou et al. (2010) conducted a cohort in Reverse oblique intertrochanteric femoral fractures (n=63). Intramedullary Hip Screw (IMHS) was evaluated on Satisfactory fracture reduction. The Intramedullary Hip Screw for reverse oblique intertrochanteric femoral fractures achieved satisfactory fracture reduction in 88% of patients, with a 30-day mortality of 6.5%.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: