This is the authors' abstract. We don't add key points for this paper.
This article presents the design, development, and characterization of a double-bridge electrostatically actuated micromirror for multiobject spectroscopy (MOS). The proposed structure is an improvement over singlebridge micromirrors in terms of aperture size, pull-in voltage, degrees of freedom, and fill factor. The two-axis symmetric rotation mechanism of the proposed micromirror is achieved by bending and twisting action of the suspended cantilevers which is contrary to the twisting cantilevers of a conventional one-axis torsional micromirror. The placement of anchor and cantilevers under the mirror plate results in a high fill factor when arranged in a 2-D array. The analytical modeling, design optimization, and static and dynamic analysis are done using finite-element method (FEM) in Coventorware. An optimized design is fabricated using a simple approach of surface micromachining and electroplating. For a micromirror of size 200 μm x 200 μm and the actuation gap of 2.5 μm, the device exhibits a tilt angle of 1.5oat a pull-in voltage of 23.1 V, a switching time of 38 μs, and the resonance frequency of 35.23 kHz. A 3 x 3 array of the micromirror is demonstrated with a fill factor of more than 95%. The deflection range can be increased by simply increasing the thickness of the sacrificial layer and without any major process modification.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: