Key result
Anesthetic management utilizing rapid sequence induction, lung isolation, and delayed cardioversion successfully facilitated the surgical repair of an atrio-esophageal fistula in a 56-year-old man.
Case Report (n=1)
Careful anesthetic management, including avoiding positive pressure ventilation before securing the airway and delaying cardioversion, can prevent fatal air embolization and massive bleeding during surgical repair of atrio-esophageal fistulas.
May guide anesthetic planning in rare atrio-esophageal fistula repairs; leaves open need for validation beyond this single case.
Introduction: Atrio-esophageal fistula is a rare but often fatal complication of radiofrequency ablation for atrial fibrillation. Here we report a successful case in anesthetic management of surgical repair of atrio-esophageal fistula. Case Report: The patient was a 56-year-old man status post radiofrequency ablation for atrial fibrillation one month before presenting with fever and symptoms and signs of cerebral emboli. He was diagnosed as having atrio-esophageal fistula, which required emergent surgical repair. In the operating room, rapid sequence induction was performed with avoidance of positive pressure ventilation before securing airway. Double lumen tube was used for lung isolation for left thoracotomy. Upon exploration, a small fistula was identified. Both atrial and esophageal defects were ligated and an intercostal muscle flap was placed. The patient’s heart rhythm was atrial flutter/atrial fibrillation with marginal hemodynamics during the procedure, but cardioversion was delayed until the fistula was repaired and no remaining air, blood clot or gastric content in the heart was confirmed by epicardial ultrasound. The patient tolerated the surgery and was transferred to ICU, intubated and ventilated. He recovered from surgery and was transferred to a rehabilitation hospital with residual expressive aphasia. Conclusion: We had a successful case in anesthetic management for surgical repair of atrio-esophageal fistula by preventing massive bleeding as well as multiple air embolization through the fistula.
No takes yet. Share an insight, caveat, or question.
Yasuda et al. (2013) conducted a case report in Atrio-esophageal fistula following radiofrequency ablation for atrial fibrillation (n=1). Anesthetic management (rapid sequence induction, lung isolation, delayed cardioversion) was evaluated on Successful surgical repair and recovery. Anesthetic management utilizing rapid sequence induction, lung isolation, and delayed cardioversion successfully facilitated the surgical repair of an atrio-esophageal fistula in a 56-year-old man.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: