Key result
Microfluidic assays enable biomimetic modeling of microvascular thrombosis across shear stresses using minimal blood volumes.
Microfluidic technology enables low-volume (~100 μl), high-throughput clinical assays of shear-dependent platelet function and coagulation as well as endothelialized biomimetic microvascular models, but cannot replicate the inertial fluid dynamics of large arteries.
Answers are grounded in this paper and cite their sources.
May enable low-volume platelet assays in clinical labs; leaves open validation for routine use and large-artery modeling.
PURPOSE OF REVIEW: This article reviews the application of microfluidic technologies in hemostasis. The emphasis is on promising developments in devices for clinical applications and novel approaches to modeling complex hemodynamics. RECENT FINDINGS: Microfluidics combined with micropatterning of prothrombotic substrates provides devices for measuring platelet function and coagulation with low blood volumes (∼100 μl) over a wide range of shear stresses. This technology has been applied to the diagnosis of bleeding and thrombotic disorders, as well as to dosing and monitoring of anticoagulation and antiplatelet agents. Microfluidic devices that mimic vascular geometries such as bifurcations, stenosis, and complex interconnected networks yield complex flow fields that have revealed new mechanisms of platelet adhesion and aggregation. Applying techniques from tissue engineering by endothelializing these networks is beginning to close the gap between in-vitro and in-vivo models of vascular injury. SUMMARY: Microfluidic technology enables researchers to create in-vitro models of vascular disease with unprecedented control of the biochemical and biophysical conditions. Two promising directions are flow-dependent clinical assays and biomimetic vascular networks. These approaches are particularly well suited for modeling the microvasculature. However, caution should be used when extrapolating results from microfluidic channels to the pathophysiology of thrombosis in large arteries and veins.
No takes yet. Share an insight, caveat, or question.
Neeves et al. (2013) conducted a review in Bleeding and thrombotic disorders (hemostasis and thrombosis). Microfluidic devices and micropatterning technologies vs. Conventional flow assays (annular and parallel plate chambers) and static assays was evaluated on Measurement of platelet function, coagulation, and thrombus formation under flow. Microfluidic technologies measure platelet function and coagulation using low blood volumes (~100 μl) across a wide range of shear stresses, enabling biomimetic modeling of microvascular thrombosis.
Synapse has enriched 10 related papers. Consider them for comparative context: