Key result
The abstract introduces the WIPER TRUST technique for grasping leads without free ends during transvenous lead extraction, but reports no clinical outcomes.
Why the study?
In complex transvenous lead extraction cases with prolonged dwell times, a combined superior and femoral approach may be required for safe and effective removal.
Answers are grounded in this paper and cite their sources.
Describes the WIPER TRUST technique for grasping leads without free ends during complex transvenous lead extraction procedures.
Transvenous lead extraction (TLE) is a cornerstone of long-term management for patients with cardiac implantable electronic devices. The indications for TLE include lead infections, lead malfunction, and the requirement for lead replacement or an upgrade to cardiac resynchronization therapy.1 The superior approach is commonly used as the first-line strategy for TLE. In complex cases, such as lead extraction with prolonged dwell times, a combined superior and femoral approach may be required to ensure safe and effective removal.
No takes yet. Share an insight, caveat, or question.
Kasai et al. (2025) studied Patients with cardiac implantable electronic devices requiring transvenous lead extraction. Wire In Pigtail cathEteR ThRoUgh Snare Twice (WIPER TRUST) technique was evaluated. The abstract introduces the WIPER TRUST technique for grasping leads without free ends during transvenous lead extraction, but reports no clinical outcomes.