Answers are grounded in this paper and cite their sources.
An isostatic aroma permeation measurement system was developed using a customized permeation cup and dynamic SPME‐GC‐FID coupled to a flow‐cell unit. The limit of quantitation (LOQ) of the method ranged from 0.012 to 0.054 mg/m 3 with a PDMS‐coated SPME Arrow, with typical linearity from 5 to 600 mg/m 3 . The system's repeatability on a polyethylene terephthalate (PET) film was between 8.7% and 25.0% (%RSD, n = 4). The results were verified using headspace GC–MS and thermal desorption GC–MS, with relative average deviation (%RAD) ranging from 6.0% to 20.7%. The aroma barrier performance of six film samples, including PET, biaxially oriented polypropylene (BOPP) and vacuum metalized polyethylene (PET//VMPE), was compared using this method with a mixture of five model aroma compounds, such as 2‐methyl pyrazine, 2‐heptanone and benzaldehyde. This method provides a sensitive, automated and low‐cost solution for evaluating the aroma barrier performance of polymer films, with potential applications in the packaging industry.
No takes yet. Share an insight, caveat, or question.
Zou et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: