Key result
Low serum albumin was associated with higher mortality after TAVR (HR 3.03; 95% CI 1.66-5.26; P<.001) and significantly improved the predictive ability of STS and EuroSCORE-2 scores.
Why the study?
Does the addition of baseline serum albumin to STS and EuroSCORE-2 scores improve prediction of 1-year mortality in individuals undergoing TAVR?
Cohort (n=426)
No
Does the addition of baseline serum albumin to STS and EuroSCORE-2 scores improve prediction of 1-year mortality in individuals undergoing TAVR?
Hazard Ratio: 3.03 (95% CI 1.66–5.26)
p-value: p=<.001
The addition of baseline serum albumin, a marker of frailty, significantly improves the predictive accuracy of STS and EuroSCORE-2 scores for 1-year mortality after TAVR.
Adding serum albumin may refine post-TAVR mortality prediction; leaves open whether it alters clinical decision-making.
OBJECTIVES: The ability of the Society of Thoracic Surgeons (STS) and European System for Cardiac Operative Risk Evaluation (EuroSCORE)-2 scores to predict outcomes after transcatheter aortic valve replacement (TAVR) is insufficient. Frailty and serum albumin as a frailty marker were shown to correlate with prognosis after TAVR. We sought to evaluate the additive value of serum albumin to STS and EuroSCORE-2 scores to predict mortality in individuals undergoing TAVR. DESIGN: Retrospective analysis. SETTING: Tertiary-care hospital prospective registry. PARTICIPANTS: Individuals who underwent TAVR (N = 426). MEASUREMENTS: We compared survival rates according to median baseline albumin levels (4 g/dL), STS score (4.5%), and EuroSCORE-2 (3.45%). Participants were divided into four groups according to median serum albumin and median STS and EuroSCORE-2 scores (high vs low), and 1-year survival rates were compared. A category-free net reclassification index (NRI) was calculated to compare the ability of a model of STS or EuroSCORE-2 alone to classify mortality risk with and without the addition of baseline serum albumin. RESULTS: Participants with low albumin levels had higher mortality (hazard ratio (HR) = 3.03, 95% confidence interval (CI) = 1.66-5.26, P < .001). Participants with low serum albumin and a high STS (HR = 4.55, 95% CI = 2.21-9.38, P < .001) or EuroSCORE-2 (HR = 2.72, 95% CI = 1.48-5.06, P = .001) score had higher mortality. Using NRI analysis, a model that included albumin in addition to STS correctly reclassified 42% of events (NRI = 0.58) and a model that included albumin in addition to EuroSCORE-2 correctly reclassified 44% of events (NRI = 0.64). CONCLUSION: Serum albumin, as a marker of frailty, can significantly improve the ability of STS and EuroSCORE-2 scores to predict TAVR-related mortality.
No takes yet. Share an insight, caveat, or question.
Grossman et al. (2017) conducted a cohort in Transcatheter aortic valve replacement (TAVR) (n=426). Low serum albumin vs. High serum albumin was evaluated on Mortality (HR 3.03, 95% CI 1.66-5.26, p=<.001). Low serum albumin was associated with higher mortality after TAVR (HR 3.03; 95% CI 1.66-5.26; P<.001) and significantly improved the predictive ability of STS and EuroSCORE-2 scores.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: