Key result
CT-based measurement of abdominal subcutaneous and visceral adipose tissues using AZE Virtual Place software demonstrated excellent reproducibility, with inter-rater coefficients of variation of 1.43% for SAT and 2.20% for VAT.
Cross-Sectional (n=40)
No
Answers are grounded in this paper and cite their sources.
CT-based measurement of abdominal subcutaneous and visceral adipose tissues using AZE Virtual Place software demonstrates excellent inter-rater reproducibility and intra-rater repeatability.
Excessive accumulation of abdominal adipose tissue is a widely recognized as a major feature of obesity, and it can be quantified by dual-energy x-ray absorptiometry (DXA). However, in a phantom study, the inter- and intra-instrument reliability of DXA remains unpredictable. Thus, we attempted to determine the precision of estimates from computer tomography-based measurements and analysis with AZE Virtual Place software. To determine the inter-rater reproducibility and intra-rater repeatability of adipose tissue area estimates, we used the automatic boundary-tracing function of the AZE Virtual Place to generate cross-sectional areas of subcutaneous and visceral adipose tissues from the abdomen of reconstructed CT images. The variability of inter-rater and intra-rater estimates expressed as the coefficient of variation ranged from 0.47% to 1.43% for subcutaneous adipose tissue and 1.08% to 2.20% for visceral adipose tissue; the optimal coefficient of variation of the fat rate calculation ranged from 0.55% to 1.13%, respectively. There was high and significant correlation between adipose tissue areas as estimated in 40 obese subjects by two raters or repeatedly on 20 obese subjects by either rater. This indicates excellent reproducibility and repeatability via a computer tomography-based measurement of abdominal subcutaneous and visceral adipose tissues.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2017) conducted a cross-sectional in Obesity and Metabolic Syndrome (n=40). CT-based measurement using AZE Virtual Place software vs. Inter-rater and intra-rater comparisons was evaluated on Inter-rater reproducibility and intra-rater repeatability of subcutaneous and visceral adipose tissue area estimates (Inter-rater CV 1.43% for SAT and 2.20% for VAT; r=0.99877 for SAT and r=0.99363 for VAT, p=<0.0001). CT-based measurement of abdominal subcutaneous and visceral adipose tissues using AZE Virtual Place software demonstrated excellent reproducibility, with inter-rater coefficients of variation of 1.43% for SAT and 2.20% for VAT.
Synapse has enriched 10 related papers. Consider them for comparative context: