Key result
A wavelet transform based ECG delineator achieved high sensitivity and positive predictive value and outperformed temporal delineation techniques in Wistar rats.
Why the study?
Does a wavelet transform based ECG delineator improve ECG wave delineation performance compared to temporal analysis in Wistar rats?
Does a wavelet transform based ECG delineator improve ECG wave delineation performance compared to temporal analysis in Wistar rats?
A wavelet transform-based ECG delineator provides highly accurate automated delineation of ECG waveforms in Wistar rat models, outperforming temporal analysis techniques.
Answers are grounded in this paper and cite their sources.
Animal study supports WT-based ECG delineation in rats; leaves open clinical translation and validation.
BACKGROUND AND OBJECTIVES: The extensive use of electrocardiogram (ECG) recordings during experimental protocols using small rodents requires an automatic delineation technique in the ECG with high performance. It has been shown that the wavelet transform (WT) based ECG delineator is a suitable tool to delineate electrocardiographic waveforms. The aim of this work is to implement and evaluate the ECG waves delineation in Wistar rats applying WT. We also describe the ECG signal of the Wistar rats giving the characteristics of its spectrum among other useful information. METHODS: We evaluated a delineator based on WT in a Wistar rat electrocardiograms database which was annotated manually by experienced observers. RESULTS: The delineation showed an "overall performance" such as sensitivity and a positive predictive value of 99.2% and 83.9% for P-wave, 100% and 99.9% for QRS complex, and 100% and 99.8% for T-wave, respectively. We also compared temporal analysis based ECG delineator with the WT based ECG delineator in RR interval, QRS duration, QT interval, and T-wave peak-to-end duration. The results showed that WT outperforms the temporal delineation technique in all parameters analyzed. CONCLUSIONS: Finally, we propose a WT based ECG delineator as a methodology to implement in a wide diversity of experimental ECG analyses using Wistar rats.
No takes yet. Share an insight, caveat, or question.
Arini et al. (2018) studied Wistar rat electrocardiograms. Wavelet transform (WT) based ECG delineator vs. Temporal analysis based ECG delineator was evaluated on ECG waves delineation performance (sensitivity and positive predictive value). A wavelet transform based ECG delineator achieved high sensitivity and positive predictive value and outperformed temporal delineation techniques in Wistar rats.
Synapse has enriched 10 related papers. Consider them for comparative context: