Electrochemical reduction properties of carmustine, an anticancer medication, were studied at glassy carbon electrode using cyclic voltammetry. A well defined irreversible reduction peak was obtained at -1.001V potential vs. Ag/AgCl reference electrode in BR buffer of pH 6.3. Mass transport in the reduction process was found to be diffusion controlled and a reduction mechanism was proposed on the basis of kinetic parameters which were calculated using experimental data. Furthermore, determination of carmustine in bulk form and human urine as a biological sample was carried out by differential pulse cathodic adsorptive stripping voltammetry using optimised parameters. Peak current was linear in the concentration range of 6.510 -6 -1.06510 -3 M. LOD and LOQ were observed to be 4.1610 -7 M and 1.3910 -6 M respectively.