Key result
Compared to radiography, hip ultrasonography demonstrated a sensitivity of 45.7% and specificity of 100% for detecting abnormal hip development in treated DDH.
Why the study?
The study aimed to compare radiographic and ultrasonographic findings in patients treated for developmental dysplasia of the hip.
Does hip ultrasonography accurately detect abnormal hip development compared to radiography in infants treated for DDH?
Observational (n=88)
Does hip ultrasonography accurately detect abnormal hip development compared to radiography in infants treated for DDH?
Hip maturation apparent on ultrasonography may not be consistent with radiographic hip development in infants treated for DDH, demonstrating low sensitivity compared to radiography.
This is the authors' abstract. We don't add key points for this paper.
Currently, hip sonography is used for early diagnosis and for monitoring developmental dysplasia of the hip (DDH) treatment in many countries. An early pioneer of ultrasonography for early diagnosis of DDH was Graf. Based on the Graf approach, hip ultrasonography is more sensitive and specific than radiography for the diagnosis of DDH, because of its capability to show cartilaginous structures of the hip joint. The aim of this study was to compare radiographic and ultrasonographic findings in patients treated for DDH. This study included 88 infants (98hips) treated for DDH. Radiography was simultaneously used for treatment and follow-up evaluation in addition to ultrasonography after six months of age. A retrospective evaluation was made of the ultrasonographs and radiographs of these infants. Of the total 98 hips, 28 were normal both ultrasonographically and radiographically, and a pathologic hip was demonstrated in 32 hips both sonographically and radiographically. Hip ultrasonography showed abnormal development in 32 hips, while radiography showed abnormal development in 70 hips. In 38 hips, the findings were normal according to ultrasonography but pathological according to radiography. There were no hips that were normal radiographically but pathological sonographically. When radiography is accepted as the standard imaging method in our study patients, the sensitivity and specificity of hip ultrasonography were determined as 45.7% [95% confidence interval (CI): 41.5-45.7] and 100% (95% CI: 89.4-100), respectively. These findings suggest that hip maturation apparent on ultrasonography may not be consistent with radiographic hip development in infants treated for DDH.
Answers are grounded in this paper and cite their sources.
Hip ultrasonography's low sensitivity cautions against sole use for DDH monitoring; leaves open need for prospective imaging validation studies.
No takes yet. Share an insight, caveat, or question.
Atalar et al. (2019) conducted an observational in Developmental dysplasia of the hip (DDH) (n=88). Hip ultrasonography vs. Radiography was evaluated on Detection of abnormal hip development (Sensitivity 45.7%, 95% CI 41.5-45.7). Compared to radiography, hip ultrasonography demonstrated a sensitivity of 45.7% and specificity of 100% for detecting abnormal hip development in treated DDH.
Synapse has enriched 10 related papers. Consider them for comparative context: