Key result
Plasma GDF-15 levels were higher in patients with old myocardial infarction and heart failure compared to controls and positively correlated with collagen turnover markers.
Cross-Sectional (n=179)
No
Answers are grounded in this paper and cite their sources.
Plasma GDF-15 levels are elevated in patients with heart failure following myocardial infarction and correlate significantly with markers of collagen turnover and echocardiographic indices of ventricular dysfunction.
BACKGROUND: Growth differentiation factor (GDF)-15, a divergent member of the transforming growth factor beta super-family does appear to be up-regulated in response to experimental pressure overload and progression of heart failure (HF). HF frequently develops after myocardial infarction (MI), contributing to worse outcome. The aim of this study is to assess the correlation between GDF-15 levels and markers related to collagen turnover in different stages of HF. METHODS: The study consists of a cohort of 179 patients, including stable angina pectoris patients (AP group, n = 50), old MI patients without HF (OMI group, n = 56), old MI patients with HF (OMI-HF group, n = 38) and normal Control group (n = 35). Both indicators reflecting the synthesis and degradation rates of collagen including precollagen I N-terminal peptide (PINP), type I collagen carboxy-terminal peptide (ICTP), precollagen III N-terminal peptide (PIIINP) and GDF-15 were measured using an enzyme-linked inmunosorbent assay. RESULTS: The plasma GDF-15 level was higher in OMI-HF group (1373.4 ± 275.4 ng/L) than OMI group (1036.1 ± 248.6 ng/L), AP group (784.6 ± 222.4 ng/L) and Control group (483.8 ± 186.4 ng/L) (P < 0.001). The indicators of collagen turnover (ICTP, PINP, PIIINP) all increased in the OMI-HF group compared with Control group (3.03 ± 1.02 µg/L vs. 2.08 ± 0.95 µg/L, 22.2 ± 6.6 µg/L vs. 16.7 ± 5.1 µg/L and 13.2 ± 7.9 µg/L vs. 6.4 ± 2.1 µg/L, respectively; P < 0.01). GDF-15 positively correlated with ICTP and PIIINP (r = 0.302, P < 0.001 and r = 0.206, P = 0.006, respectively). GDF-15 positively correlated to the echocardiographic diastolic indicators E/Em and left atrial pressure (r = 0.349 and r = 0.358, respectively; P < 0.01), and inversely correlated to the systolic indicators left ventricular ejection fraction and the average of peak systolic myocardial velocities (Sm) (r = -0.623 and r = -0.365, respectively; P < 0.01). CONCLUSION: Plasma GDF-15 is associated with the indicators of type I and III collagen turnover.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2016) conducted a cross-sectional in Myocardial infarction and heart failure (n=179). Old myocardial infarction with heart failure vs. Healthy controls was evaluated on Plasma GDF-15 level (p=<0.001). Plasma GDF-15 levels were higher in patients with old myocardial infarction and heart failure compared to controls and positively correlated with collagen turnover markers.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: