Key result
Older age was associated with lower BOLD and low-frequency (1-12 Hz) EEG variability, but increased beta-band (15-25 Hz) EEG variability, with no correlation between EEG and fMRI measures.
Why the study?
It remains unclear whether measures of brain signal variability identified with hemodynamic versus electrophysiological methods reflect the same underlying physiology during aging.
Cross-Sectional (n=189)
BOLD and EEG signal variability both reflect aging-related processes but likely originate from different physiological mechanisms, as they do not correlate with each other.
Independent BOLD and EEG variability changes with age; leaves open distinct mechanisms and multimodal biomarker potential.
Variability of neural activity is regarded as a crucial feature of healthy brain function, and several neuroimaging approaches have been employed to assess it noninvasively. Studies on the variability of both evoked brain response and spontaneous brain signals have shown remarkable changes with aging but it is unclear if the different measures of brain signal variability - identified with either hemodynamic or electrophysiological methods - reflect the same underlying physiology. In this study, we aimed to explore age differences of spontaneous brain signal variability with two different imaging modalities (EEG, fMRI) in healthy younger (25 ± 3 years, N = 135) and older (67 ± 4 years, N = 54) adults. Consistent with the previous studies, we found lower blood oxygenation level dependent (BOLD) variability in the older subjects as well as less signal variability in the amplitude of low-frequency oscillations (1-12 Hz), measured in source space. These age-related reductions were mostly observed in the areas that overlap with the default mode network. Moreover, age-related increases of variability in the amplitude of beta-band frequency EEG oscillations (15-25 Hz) were seen predominantly in temporal brain regions. There were significant sex differences in EEG signal variability in various brain regions while no significant sex differences were observed in BOLD signal variability. Bivariate and multivariate correlation analyses revealed no significant associations between EEG- and fMRI-based variability measures. In summary, we show that both BOLD and EEG signal variability reflect aging-related processes but are likely to be dominated by different physiological origins, which relate differentially to age and sex.
No takes yet. Share an insight, caveat, or question.
Kumral et al. (2019) conducted a cross-sectional in Healthy aging (n=189). Older age vs. Younger age was evaluated on Spontaneous brain signal variability (BOLD and EEG). Older age was associated with lower BOLD and low-frequency (1-12 Hz) EEG variability, but increased beta-band (15-25 Hz) EEG variability, with no correlation between EEG and fMRI measures.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: