Answers are grounded in this paper and cite their sources.
Large-scale reverse electrodialysis (RED) stacks are essential for practical power generation; however water and salt transport through ion-exchange membranes become significant at large scale and reduce energy efficiency. In this study, water and salt transport in a large-scale RED stack were quantitatively evaluated, and the associated energy losses were analyzed. For model and natural seawater, non-electrical salt permeation was a major source of energy loss and became dominant under high-flow-rate conditions. In contrast, for model and natural RO brine, energy losses associated with water transport were relatively large, reaching up to one-third of the total loss. The dominant loss mechanism depended on the feed solution: salt-transport losses accounted for up to 82% of the total energy loss in model seawater, whereas water-transport losses accounted for up to 45% in model RO brine. At low flow rates, losses due to concentration polarization and concentration changes along the flow direction were significant, while at high flow rates these contributions decreased and losses due to water and salt transport became dominant. These results highlight that both operating conditions and membrane properties are critical for improving large-scale RED performance. Membranes with low salt permeability are suitable for seawater, whereas membranes with reduced water permeability are preferable for RO brine.
No takes yet. Share an insight, caveat, or question.
Sugimoto et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: