Key result
Subcutaneous ICD shows no difference in physical functioning or quality of life versus transvenous ICD.
Why the study?
The extrathoracic S-ICD was developed to overcome lead-related complications of the TV-ICD, resulting in different complication profiles that might impact patient perceptions and quality of life.
Does subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy improve or differ in quality of life and physical functioning compared to transvenous implantable cardioverter-defibrillator (TV-ICD) therapy in patients with an ICD indication without a need for pacing?
RCT (n=849)
Open-label (both patients and physicians were not blinded to the study arms)
Randomly allocated 1:1 with stratification according to the center
Yes
Does subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy improve or differ in quality of life and physical functioning compared to transvenous implantable cardioverter-defibrillator (TV-ICD) therapy in patients with an ICD indication without a need for pacing?
In this prespecified secondary analysis of the randomized PRAETORIAN trial, overall quality of life did not differ between patients receiving an S-ICD versus a TV-ICD over 30 months, although receiving a shock transiently reduced quality of life in both groups.
Answers are grounded in this paper and cite their sources.
QoL equivalence supports flexible S-ICD or TV-ICD selection; extends PRAETORIAN trial to patient-reported physical and mental health outcomes.
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device. Subsequently, complications differ between these 2 implantable cardioverter-defibrillators, which might impact patient perceptions of the therapies. This prespecified secondary analysis of the PRAETORIAN trial evaluates differences in quality of life. METHODS: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) randomized patients with an implantable cardioverter-defibrillator indication, without the need for pacing to S-ICD or TV-ICD therapy. Two questionnaires were collected at baseline, discharge, 12 months, and 30 months. The Duke Activity Status Index measures cardiac-specific physical functioning, and the 36-Item Short Form Health Survey measures physical and mental well-being, with the subscales bodily pain and mental health being of interest in this analysis. Mann-Whitney U tests were used to compare study arms, and a mixed model was used to describe the questionnaire outcomes over time. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). In the S-ICD group, 20% were women versus 19% in the TV-ICD group. The median age was 63 (interquartile range, 54–69) years in the S-ICD group versus 64 (interquartile range, 56–69) years in the TV-ICD group. There were no significant differences in the Duke Activity Status Index and 36-Item Short Form Health Survey subscales for bodily pain and mental health between the groups at any time point. Patients with a shock in the last 90 days had significantly lower scores for social functioning ( P =0.008) and role limitations due to emotional problems ( P =0.001) than patients without a shock, but this effect did not differ between treatment arms. CONCLUSIONS: In a large randomized cohort of patients with an S-ICD or TV-ICD, no difference in overall quality of life was observed. However, implantable cardioverter-defibrillator shocks resulted in a reduction in quality of life, regardless of the device type or appropriateness. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.
No takes yet. Share an insight, caveat, or question.
Knops et al. (2024) conducted an RCT in Class I or IIa indication for implantable cardioverter-defibrillator (ICD) therapy without pacing indication (n=849). Subcutaneous implantable cardioverter-defibrillator (S-ICD) vs. Transvenous implantable cardioverter-defibrillator (TV-ICD) was evaluated on Quality of life measured by Duke Activity Status Index (DASI) and 36-Item Short Form Health Survey (SF-36) bodily pain and mental health subscales at baseline, discharge, 12 months, and 30 months (p=>0.05). Subcutaneous ICD and transvenous ICD therapy resulted in no significant differences in cardiac-specific physical functioning (DASI) or SF-36 bodily pain and mental health subscales over 30 months.
Synapse has enriched 10 related papers. Consider them for comparative context: