Key result
Hybrid aortic reconstruction in 6 infants with recurrent aortic obstruction after stage 1 palliation resulted in no procedure-related complications, with 3 progressing well and 3 deaths at 4.8 years.
Why the study?
Is hybrid aortic reconstruction safe and effective for treating recurrent aortic obstruction after stage 1 palliation in infants with hypoplastic left heart syndrome?
Case Report (n=6)
Is hybrid aortic reconstruction safe and effective for treating recurrent aortic obstruction after stage 1 palliation in infants with hypoplastic left heart syndrome?
Hybrid aortic reconstruction allows for the safe placement of stents that can be redilated to accommodate somatic growth in small infants with recurrent aortic obstruction after stage 1 palliation.
Answers are grounded in this paper and cite their sources.
May support feasibility of hybrid reconstruction without procedural complications; leaves open long-term efficacy and survival in larger cohorts.
OBJECTIVE: We describe a hybrid approach to the treatment of aortic obstruction after stage 1 palliation (S1P) of hypoplastic left heart syndrome. BACKGROUND: Recurrent aortic obstruction is a common problem after S1P of hypoplastic left heart syndrome. Even mild aortic obstruction is poorly tolerated so early and definitive therapy is desirable. Although stent implantation is an effective treatment for aortic obstruction in older children and adults, technical issues due to small vessels and concerns regarding future potential for expansion have generally precluded the use of stents in this setting. METHODS: Six patients underwent hybrid aortic reconstruction (HAR) in the operating room or catheterization laboratory, with the interventional cardiologist and cardiac surgeon working in cooperation. RESULTS: Patients had a mean weight of 5.8 kg (2.9-7.7) and a mean age of 5.6 months (0.5-12.9) at the time of HAR. Five patients had undergone prior balloon angioplasty at a mean age of 2.8 months (2.1-3.5), and five had moderately depressed single ventricular function prior to HAR. The balloons used had a diameter of 7-10 mm and introducer sheath size ranged from 6 to 10 F. There were no immediate or late procedure related complications. Stent redilation was performed in 5 patients for relief of recurrent obstruction or to keep pace with somatic growth. At a median follow up of 4.8 years (0.2-7.9), there were 3 patients progressing well after Fontan palliation and 3 deaths. CONCLUSIONS: HAR allows for placement of stents that can ultimately reach adult size in small infants who have recurrent aortic obstruction after balloon angioplasty following S1P. Advantages include freedom from delivery sheath constraints when determining stent type/size, facilitation of precise stent position, and avoidance of vascular damage or hemodynamic compromise during the procedure. Longer follow-up and larger experience are required to determine if this therapy will provide a long-term solution to this difficult problem.
No takes yet. Share an insight, caveat, or question.
Kutty et al. (2011) conducted a case report in Recurrent aortic obstruction after stage 1 palliation of hypoplastic left heart syndrome (n=6). Hybrid aortic reconstruction was evaluated. Hybrid aortic reconstruction in 6 infants with recurrent aortic obstruction after stage 1 palliation resulted in no procedure-related complications, with 3 progressing well and 3 deaths at 4.8 years.
Synapse has enriched 10 related papers. Consider them for comparative context: