The fault-tolerant ability is a significant advantage of multiphase machines over the three-phase ones. Parallel connections of stator windings or converter legs are preferred to enhance the power rating or drive performance. Open-circuit faults on parallel branches are reflected as the derating of current limits for the corresponding phases, and fault-tolerant strategies are required to keep the phase currents within asymmetrical current limits. This article analyzes the optimal phase current trajectories of a five-phase induction machine under three different faulty scenarios in parallel situations and then proposes the offline optimized current trajectory tracking (OCTT) fault-tolerant strategy, which can reach the maximum achievable fault-tolerant power while guaranteeing optimized ohmic losses over the full power range. Furthermore, based on the generalized symmetrical components theory, an extended rotor field-oriented control (RFOC) is proposed to realize the OCTT mode in field-oriented control. Experimental results confirm the efficiency improvement of the OCTT mode in the full-power-range operation and verify the asymmetrical current trajectory tracking ability of the extended RFOC.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2019) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: