Answers are grounded in this paper and cite their sources.
Comparison of the pre- and postoperative air- and bone-conduction thresholds in 22 subjects in whom successful myringoplasty was performed has been made in the conventional and extended high-frequency ranges. Air-conduction thresholds improved through 4 kHz, but were elevated postoperatively for the frequencies 6 through 18 kHz. Postoperative bone-conduction thresholds were elevated at 0.25 and 0.5 kHz, were lower by 2-8 dB for 1 through 3 kHz and not significantly altered in the extended high-frequency range of 8 through 16 kHz. The extended high-frequency air-conduction threshold loss following myringoplasty in this study is, therefore, due to changes in middle ear transmission and is not indicative of iatrogenic cochlear damage.
No takes yet. Share an insight, caveat, or question.
Mair et al. (1994) studied this question.