Key result
Providing an implantable cardioverter-defibrillator decision aid before a clinical encounter resulted in similar overall knowledge scores compared to providing it after the visit.
Why the study?
Although shared decision-making has become a focus of health policy, there is little consensus regarding which outcomes to prioritize for policy-mandated shared decision-making.
RCT (n=24)
Block-randomized in 1-month blocks
Yes
Highlights the lack of consensus on prioritizing outcomes for policy-mandated shared decision-making regarding implantable cardioverter-defibrillators.
Answers are grounded in this paper and cite their sources.
Lack of consensus on prioritized outcomes for policy-mandated shared decision-making leaves open which metrics to adopt; further research needed to align stakeholders.
Shared decision-making has become a new focus of health policy. Though its core elements are largely agreed upon, there is little consensus regarding which outcomes to prioritize for policy-mandated shared decision-making.
No takes yet. Share an insight, caveat, or question.
A 2021 study conducted an RCT in Primary prevention implantable cardioverter-defibrillator (ICD) implantation (n=24). ICD Decision Aid (DA) provided 30 minutes prior to consultation vs. ICD Decision Aid (DA) provided at the end of the visit was evaluated on Overall knowledge regarding ICDs (Composite Score). Providing an implantable cardioverter-defibrillator decision aid before a clinical encounter resulted in similar overall knowledge scores compared to providing it after the visit.
Synapse has enriched 10 related papers. Consider them for comparative context: