Fluid flows in a two-dimensional channel with atomically rough walls were studied by molecular-dynamics simulations. Both sinusoidally and randomly roughened walls with various roughness amplitudes A were used. It was found that the no-slip condition arises when the molecular mean free path l is comparable with A. Therefore the ratio l/A should be employed to validate the no-slip condition, rather than the traditionally used ratio of the mean free path to the channel or tube diameter (Knudsen number).
No takes yet. Share an insight, caveat, or question.
Mo et al. (1990) studied this question.