The decay of neutral copper vapour density which follows the extinction of a high current (2-11 kA) vacuum arc between copper electrodes has been measured. The results show that during the period 1-8 ms from current zero the vapour density decays at least an order of magnitude slower than expected on the assumption that vapour atoms generated by the arc move freely to the electrode and vacuum chamber surfaces where they condense. The results can be explained, however, if it is assumed that the vapour is produced by evaporation from molten droplets which are emitted from the cathode spots.
No takes yet. Share an insight, caveat, or question.
Jenkins et al. (1975) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: