Key result
The three-dimensional transcranial Doppler scanner successfully detected the M1 portion of the middle cerebral artery in 100% of healthy controls, 87% of cerebral infarction patients, and 100% of TIA patients, showing good agreement with carotid angiography.
Why the study?
Does the three-dimensional transcranial Doppler scanner accurately detect cerebral blood flow and agree with carotid angiography in patients with cerebral infarction or TIA?
Cross-Sectional (n=43)
No
Does the three-dimensional transcranial Doppler scanner accurately detect cerebral blood flow and agree with carotid angiography in patients with cerebral infarction or TIA?
The three-dimensional transcranial Doppler scanner is a useful non-invasive tool that provides high detection rates and agrees well with carotid angiography for evaluating intracranial hemodynamics.
Answers are grounded in this paper and cite their sources.
Should not yet alter stroke imaging protocols; leaves open 3D transcranial Doppler utility pending prospective validation.
We examined the usefulness of the three dimensional transcranial Doppler scanner (Trans-scan: TS), and compared it with the findings of carotid angiography (CAG) . The flow of Ml portion of middle cerebral artery was detectable in 9 cases out of 9 control groups (100%), 26out of 30 cases of cerebral infarction (87%) and 4 out of 4 cases of TIA (100%) .The blood flow courses and stenosis of the middle cerebral artery observed by TS agreed with those observed by CAG.The direction of the collateral blood flow was also observed by TS. But blood flow velocity could not be represented in some cases of serious cerebral arteriosclerosis which have tortuous arteries.This scanner could reproduce the angle at the time of measurement by the image and we found the reproducibility improved.TS was considered to have greater usefulness than the conventional method by transcranial Doppler.
No takes yet. Share an insight, caveat, or question.
Yoneyama et al. (1989) conducted a cross-sectional in Cerebral infarction and Transient Ischemic Attack (TIA) (n=43). Three dimensional transcranial Doppler scanner (Trans-scan) vs. Carotid angiography (CAG) was evaluated on Detection rate of the M1 portion of the middle cerebral artery. The three-dimensional transcranial Doppler scanner successfully detected the M1 portion of the middle cerebral artery in 100% of healthy controls, 87% of cerebral infarction patients, and 100% of TIA patients, showing good agreement with carotid angiography.
Synapse has enriched 10 related papers. Consider them for comparative context: