Key result
The fluorescence dilution technique successfully measured the albumin reflection coefficient in isolated glomeruli, revealing reduced coefficients in hypertensive and diabetic rat models that correlated with proteinuria.
The fluorescence dilution technique provides a high-throughput method to measure albumin reflection coefficient in isolated glomeruli, allowing assessment of glomerular injury in hypertensive and diabetic models.
New fluorescence method quantifies σAlb in isolated rat glomeruli; extends preclinical tools but leaves clinical translation open.
This study describes a high-throughput fluorescence dilution technique to measure the albumin reflection coefficient (σAlb) of isolated glomeruli. Rats were injected with FITC-dextran 250 (75 mg/kg), and the glomeruli were isolated in a 6% BSA solution. Changes in the fluorescence of the glomerulus due to water influx in response to an imposed oncotic gradient was used to determine σAlb. Adjustment of the albumin concentration of the bath from 6 to 5, 4, 3, and 2% produced a 10, 25, 35, and 50% decrease in the fluorescence of the glomeruli. Pretreatment of glomeruli with protamine sulfate (2 mg/ml) or TGF-β1 (10 ng/ml) decreased σAlb from 1 to 0.54 and 0.48, respectively. Water and solute movement were modeled using Kedem-Katchalsky equations, and the measured responses closely fit the predicted behavior, indicating that loss of albumin by solvent drag or diffusion is negligible compared with the movement of water. We also found that σAlb was reduced by 17% in fawn hooded hypertensive rats, 33% in hypertensive Dahl salt-sensitive (SS) rats, 26% in streptozotocin-treated diabetic Dahl SS rats, and 21% in 6-mo old type II diabetic nephropathy rats relative to control Sprague-Dawley rats. The changes in glomerular permeability to albumin were correlated with the degree of proteinuria in these strains. These findings indicate that the fluorescence dilution technique can be used to measure σAlb in populations of isolated glomeruli and provides a means to assess the development of glomerular injury in hypertensive and diabetic models.
No takes yet. Share an insight, caveat, or question.
Fan et al. (2015) studied Glomerular permeability. Fluorescence dilution technique was evaluated on Albumin reflection coefficient. The fluorescence dilution technique successfully measured the albumin reflection coefficient in isolated glomeruli, revealing reduced coefficients in hypertensive and diabetic rat models that correlated with proteinuria.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: