Key result
The TAXUS Petal paclitaxel-eluting bifurcation stent resulted in a 3.7% rate of the 30-day composite primary endpoint, though device delivery success was relatively low at 73.5%.
Why the study?
Does the TAXUS Petal paclitaxel-eluting bifurcation stent provide safe and feasible outcomes in patients with bifurcation lesions?
Does the TAXUS Petal paclitaxel-eluting bifurcation stent provide safe and feasible outcomes in patients with bifurcation lesions?
The first-generation TAXUS Petal paclitaxel-eluting bifurcation stent demonstrated satisfactory clinical and angiographic outcomes when successfully delivered, though its design requiring rotational alignment resulted in challenging delivery.
Low delivery success limits feasibility despite low events; hypothesis-generating for dedicated bifurcation stent refinement.
AIMS: This first human use (FHU) study in bifurcation lesions evaluated safety and feasibility of the TAXUS Petal paclitaxel-eluting dedicated bifurcation stent. METHODS AND RESULTS: This prospective, single-arm, multicentre study had a composite primary endpoint of 30-day death, myocardial infarction (MI), and target vessel revascularisation (TVR). Angiographic and intravascular ultrasound follow-up was at six months with clinical follow-up through five years. Mean age (N=28) was 60.9 + or - 9.3 years and 17.9% of patients had medically treated diabetes. Main branch (MB) lesion length was 13.8 + or - 5.9 mm with 4.4 + or - 2.5 mm in the side branch (SB). TAXUS Petal was successfully implanted in 89.3% of patients (25/28). On a per device basis, 73.5% (25/34) of Petal deployments were successful. The primary endpoint occurred in one patient (3.7%, in-hospital non-Q-wave MI). Through one year, TVR was 11.1%, target lesion revascularisation was 7.4%, and there were no deaths, Q-wave MIs, or stent thromboses. In-segment late loss (n=21) was 0.47 + or - 0.45 mm (proximal MB), 0.41 + or - 0.57 mm (distal MB), and 0.18 + or - 0.39 mm (SB). CONCLUSIONS: The requirement for rotational alignment made delivery of this first generation TAXUS Petal stent challenging and accounted for the relatively low device delivery success. Clinical and angiographic outcomes were satisfactory when successful delivery was achieved.
No takes yet. Share an insight, caveat, or question.
Ormiston et al. (2010) studied Bifurcation lesions (n=28). TAXUS Petal paclitaxel-eluting dedicated bifurcation stent was evaluated on Composite of 30-day death, myocardial infarction (MI), and target vessel revascularisation (TVR). The TAXUS Petal paclitaxel-eluting bifurcation stent resulted in a 3.7% rate of the 30-day composite primary endpoint, though device delivery success was relatively low at 73.5%.