Four internal quantities plus the rotor position of a rotating electrical machine suffice in order to describe its dynamic behaviour. Starting from this fact, first the space‐phasor concept is introduced as an excellent analytical tool, the expressions of the main phasors are given (special attention is paid to the analysis and the physical interpretation of the voltage space phasor) and thereafter the formulation of the theory is carried out. It is then shown that all the transient states of a converter‐fed symmetrical machine can be represented by a very simple space‐phasor diagram, analogous to the one used for describing its steady state through time phasors. The diagram and the corresponding dynamic equations are deduced in a direct and immediate way, which is very useful for studies of electronically powered AC machines. The second part of this article will discuss in detail the reasons why the phasorial representation of transients is not possible neither in the “Generalized Machine Theory,” nor in the “Space‐Vector Theory” and will provide a comparison between these three theories.
No takes yet. Share an insight, caveat, or question.
Luis Serrano-Iribarnegaray (1993) studied this question.