Answers are grounded in this paper and cite their sources.
The primary purpose of stilling basins in a hydraulic structure is to attenuate the kinetic energy of flowing water in order to prevent erosion downstream of the structure, which might potentially result in its failure. The USBR VI stilling basin is an early basin designed specifically for dissipating pipe outlet flow. This study assessed the impact of adding a sill to a type VI stilling basin on the dissipation of energy by evaluating eight distinct models. The purpose of adding the sill is to increase energy dissipation and thus reduce scouring at the downstream of the basin. The aim of this study, employing numerical modelling, was to enhance the efficiency of the USBR VI stilling basin in dissipating energy. This was achieved by investigating the impact of positioning the sill at various positions and identifying the optimal position that maximises energy dissipation. The study's findings indicate that model 2 exhibits the largest percentage of energy dissipation, reaching 86.5%. The addition of a sill at 4850 mm from the inflow pipe resulted in an improvement in the performance of the stilling basin, with the energy dissipation percentage increasing from 67.1% to 86.5%. The sill at this location produces lower pressure at the outlet section than the bench model and other models as a result of the increased fluctuations at the sills. Finally, the inclusion of adding a sill at 0.723 times the length of the basin from the inlet resulted in the highest percentage of dissipation.
No takes yet. Share an insight, caveat, or question.
Naser et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: