Why the study?
Does an extracardiac conduit with Hancock xenograft reduce right ventricular function compared to outflow tract patch or minimal ventriculotomy in patients with tetralogy of Fallot?
Does an extracardiac conduit with Hancock xenograft reduce right ventricular function compared to outflow tract patch or minimal ventriculotomy in patients with tetralogy of Fallot?
An extracardiac valved conduit in patients with tetralogy of Fallot and high right ventricular systolic pressure depresses right ventricular ejection fraction compared to other surgical approaches.
Answers are grounded in this paper and cite their sources.
May warrant caution with extracardiac conduits in tetralogy of Fallot repair; leaves open causal effects on right ventricular function pending prospective trials.
Right ventricular volume measurements and hemodynamic studies were performed in 20 patients after total correction of tetralogy of Fallot. There were 6 patients with an extracardiac conduit and Hancock xenograft (G-1), 8 with an outflow tract patch (G-2) and 6 without or with a minimal right ventriculotomy and repair of pulmonary valve (G-3). The age at the time of operation was over 3 years in each patient and averaged 5 +/- 2 (mean +/- SD) years. Right ventricular systolic pressure averaged 81 +/- 22, 55 +/- 22 and 58 +/- 30 mmHg in G-1, G-2 and G-3, respectively. Right ventriculography showed no contraction of the right ventricular free wall at the anastomosis to the conduit and poor contraction around the anastomosis in G-1. The right ventricular enddiastolic volume index (RVEDVI) was 114 +/- 31, 155 +/- 57 and 115 +/- 28 ml/m2 in G-1, G-2 and G-3, respectively. The right ventricular ejection fraction (RVEF) was 0.42 +/- 0.11 in G-1, 0.53 +/- 0.04 in G-2 (p less than 0.05, vs G-1) and 0.57 +/- 0.04 in G-3 (p less than 0.02, vs G-1). Pulmonary regurgitation was evident in 17 patients, and RVEDVI correlated well with degrees of pulmonary incompetence. Fourteen patients in G-2 and G-3 were divided into G-A and G-B to evaluate right ventricular function with or without pressure overloading of the right ventricle. G-A consisted of 7 patients with a right ventricular systolic pressure of more than 50 mmHg (74 +/- 26) and G-B of 7 patients with a value less than 50 mmHg (39 +/- 4). There was no difference in RVEDVI and RVEF between G-A and G-B. RVEF was significantly lower in G-1 than G-A (p less than 0.02) and G-B (p less than 0.05). These results suggested that an extracardiac conduit with Hancock xenograft reduced the contraction of the right ventricular free wall and induced a depressed right ventricular pump function in patients with a high right ventricular pressure.
No takes yet. Share an insight, caveat, or question.
Shimazaki et al. (1985) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: