We report on heterodyne mixing experiments between 630-820 GHz using a diffusion-cooled superconducting hot electron bolometer at intermediate frequencies from 1-2 GHz. The niobium bolometer which is cooled by diffusion of the hot electrons into a normal conductor has dimensions of 0.3 /spl mu/m/spl times/0.15 /spl mu/m and was fabricated at KOSMA with a two-step electron beam lithography process. The film thickness of the device is 30 nm with T/sub c/ of 6.1 K and /spl Delta/T/sub c/ of 0.7 K. The mixing experiments are performed with a tunerless waveguide mixer block previously used for very low-noise SIS receivers. At a physical temperature of 2.2 K, receiver noise temperatures at 666 GHz are 1500 K at 1.0 GHz intermediate frequency, increasing rapidly above 1.5 GHz. The dissipated local oscillator power is evaluated to be 65-90 nW.
No takes yet. Share an insight, caveat, or question.
Fiegle et al. (1997) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: