Answers are grounded in this paper and cite their sources.
A practical optical sensing system for the determination of chloramphenicol (CAP), utilizing molecularly imprinted polymers (MIPs) and HPLC, has been developed. The method is based on competitive displacement of a chloramphenicol-methyl red (CAP-MR) dye conjugate from specific binding cavities in an imprinted polymer by the analyte. The best of these polymers was obtained using (diethylamino)ethyl methacrylate as functional monomer at a monomer:template ratio of 2:1. HPLC with a mobile phase containing CAP-MR was used as the detection system, and injection of CAP and, to a lesser degree, thiamphenicol resulted in proportional displacement of the conjugate, which was detected at 460 nm. The detection system showed a linear response over a range of 3-1000 μg/mL and effectively detected CAP extracted from serum. This system offers a tailor-made, selective, and rapid method for CAP detection, is able to discriminate between similar molecules, and is effective below and above the therapeutic range (10-20 μg/mL serum, potentially toxic above 25 μg/mL). This technique is quite general and should enable the use of MIPs in a wide variety of applications involving the detection of families of molecules which possess a distinct arrangement of functional groups.
No takes yet. Share an insight, caveat, or question.
Levi et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: