Key result
Bovine periodontal ligament is highly compressible and functions as a porous solid matrix allowing fluid exchange during loading, with pore pressure having no influence on its mechanical response.
The periodontal ligament functions as a highly compressible, biphasic porous solid matrix through which fluid freely flows during mechanical loading, independent of environmental pore pressure.
Caution against applying bovine PDL mechanics to human care; leaves open validation in cardiovascular or periodontal models.
The periodontal ligament (PDL) functions both in tension and in compression. The presence of an extensive vascular network inside the tissue suggests a significant contribution of the fluid phase to the mechanical response. This study examined the load response of bovine PDL under different pore pressure levels. A custom-made pressure chamber was constructed. Rod-shaped specimens comprising portions of dentine, bone, and intervening layer of PDL were extracted from bovine mandibular molars. The dentine ends of the specimens were secured to the actuator while the bone ends were affixed to the load cell. The entire assemblage was surrounded by the pressure chamber, which was then filled with saline. Specimens loaded at 1.0 Hz sinusoidal displacement were subjected to four different environmental fluid pressures (i.e., pressures of 0.0-1.0 MPa). The video images recorded during the tests were analyzed to determine whether or not fluid exchange between the PDL and the surrounding medium took place during mechanical loading. A value for the tissue's apparent Poisson ratio was also determined. The following observations were made: (1) fluid was squeezed out and pumped into the ligament during the compressive and tensile loading phases, (2) the PDL was highly compressible, and (3) the pore pressure had no influence on the mechanical response of the PDL. The present tests emphasized the biphasic structure of PDL tissue, which should be considered as a porous solid matrix through which fluid can freely flow.
No takes yet. Share an insight, caveat, or question.
Bergomi et al. (2009) studied this question. Environmental fluid pressures was evaluated on Load response, fluid exchange, and apparent Poisson ratio under 1.0 Hz sinusoidal displacement. Bovine periodontal ligament is highly compressible and functions as a porous solid matrix allowing fluid exchange during loading, with pore pressure having no influence on its mechanical response.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: